HL3 Series: Premium, Two Stage Heater

 

V3_tubehtr_0 The HL3 Series, packed with quality features, represents today’s most energy efficient line of infrared tube heaters. Our patented two-stage technology, incorporated into the HL3 Series, provides more comfort while saving valuable energy dollars. In addition, the highest quality materials and construction features ensure years of reliable and efficient operation. The two stage HL3 Series represents the BEST in performance and quality!

 

FeaturesSpecificationsLiteratureParts & AccessoriesFAQBuy

 

 Specific Features

 

Tube-Features
  • Tool-free access to controls.
  • Serviceability while unit is operating.
  • Separated air and gas burner chamber.
  • Symmetrical placement of ignition tube.
  • Hinged control compartment provides ease in servicing.
  • 3-piece independent compartment cover.
  • ABS plastic air intake collar for connection to 4” PVC/DWV pipe.

 

Product Features Comparison Chart

HL3

DX3

DET3

DES3

Highly Polished Aluminum Reflectors check check check check
Coated Titanium or Aluminized Combustion Chamber check check check check
Coated Aluminized Radiant Tubes check check cross cross
Hot Surface Ignition check check cross cross
Stainless Steel Flexible Gas Connector check check check check
Two-Stage Technology check cross check cross
Interlocking Swaged Tubes check check check check
Stainless Steel Models Available check check cross cross
Reflector End Caps Included check check cross cross
Optional ‘U’ or ‘L’ Configurations Available check check check check

 

BTU Range: 65,000 – 200,000 BTU/h
Lengths: 20-70 ft.
Gas Type: Natural or Propane
Combustion Chamber: Black Coated Aluminized or Titanium
Radiant Tubes: Black Coated Aluminized Steel
Certification: CSA, IAS, CE (GTD)
Warranty: 1/5/10 (Components/Tubes/Burner)

 


 

PRODUCT SPECIFICATIONS
ELECTRICAL
• 120v, 60Hz, 3-wire
• 4.8A starting, 1.1A running
CONTROLS
• Pre & post purge
• 24V thermostat Control
• Micro-processor circuitry
TUBE CONSTRUCTION
• As shown at left
• 4″x10′ 16 ga. construction
• Labor saving, interlocking swaged tube design
REFLECTORS
• Highly polished aluminum
• End caps included
• 0°-45° rotatable angle
• Tension springs
IGNITION / SENSE
• Hot surface ignition
• Flame rod sense
• Self-diagnostic LED
VENTING
• 4″ single vent
• 6″ common vent (with single thermostat & HLRP)
• SK caps on 200 MBH models
GAS CONNECTION
• 1/2″ NPT ball valve included
• 24″ stainless flex connector provided
GAS PRESSURES
• MAN. -3.5″ NAT or 10.0″ LP
• MIN. -5.0″ NAT or 11.0 LP
• MAX. -14.0″ NAT or 14.0″ LP
COMBUSTION AIR
• Equipped for ducted air intake from roof or sidewall
KIT CONTENTS
• All hangers & couplers
• Reflector end caps
• Turbulator baffle(s)
BTU Range: 65-200 MBH
Lengths: 20-70 Ft.
Gas Type: Natural or Propane
Combustion Chamber: Black Coated Aluminized or Titanium
Radiant Tubes: Black Coated Aluminized Steel
Certification: CSA, IAS, CE (GTD)
Limited Warranty: 1-5-10 (Components-Tubes-Burner)
OPTIONAL EQUIPMENT  
“U” or “L” Configurations: Available (RUP, REP)
Stainless Steel Upgrades: Available (SSTRAO, SSFWAO)
24V Controls: Standard
Indicator Lights: Standard
Protective Guards: Available (PG)
Side Shield Extensions: Available (SSE)
Outdoor Approval: Available (OD-KIT)

 


 

AVAILABLE HL3 MODELS & CLEARANCES

Model #
Gas* MBH High/Low Length Weight

Recom. Mtg.Heights

HL3-20-65 N or LP 65/50 21’ – 9” 120# 9’ to 14’
HL3-20-75 N or LP 75/50 21’ – 9” 120# 10’ to 15’
HL3-30-65 N or LP 65/50 31’ – 5” 160# 10’ to 15’
HL3-30-75 N or LP 75/50 31’ – 5” 160# 11’ to 18’
HL3-30-100 N or LP 100/65 31’ – 5” 160# 12’ to 20’
HL3-30-125 N or LP 125/95 31’ – 5” 160# 13’ to 23’
HL3-40-65 N or LP 65/50 41’ – 1” 190# 11’ to 18’
HL3-40-75 N or LP 75/50 41’ – 1” 190# 11’ to 18’
HL3-40-100 N or LP 100/65 41’ – 1” 190# 12’ to 20’
HL3-40-125 N or LP 125/95 41’ – 1” 190# 13’ to 23’
HL3-40-150 N or LP 150/100 41’ – 1” 190# 14’ to 25’
HL3-40-175 N or LP 175/125 41’ – 1” 190# 15’ to 27’
HL3-50-125 N or LP 125/95 50’ – 9” 235# 15’ to 27’
HL3-50-150 N or LP 150/100 50’ – 9” 235# 15’ to 27’
HL3-50-175 N or LP 175/125 50’ – 9” 235# 16’ to 30’
HL3-50-200 N or LP 200/145 50’ – 9” 235# 17’ to 35’
HL3-60-150
N or LP 150/100 60’ – 5” 265# 16’ to 30’
HL3-60-175 N or LP 175/125 60’ – 5” 265# 16’ to 30’
HL3-60-200 N or LP 200/145 60’ – 5” 265# 17’ to 35’
HL3-70-175 N or LP 175/125 70’ – 1” 300# 19’ to 42’
HL3-70-200 N or LP 200/145 70’ – 1” 300# 19’ to 42’
MountingAngleChart* Specify natural (N) or propane (LP) gas.** Recommended mounting heights are provided as a guideline. Actual conditions may dictate variations from the above data.
HL3_cc_chartAlways maintain the published clearances to combustibles.Clearances published in HL3 Series manual and on warning label supersede data shown here.Place signs where necessary in accordance with ANSI Standards.

 

HL3 Series

hl3_brochure.th liogt3_manual.th   hl3_manual.th
Brochure General Manual HL3 Series Insert Manual
  
 LSHL3_HL3-Submittal_FORM_4-13.th SECTION-230000-HL3-suggested-6-11-2010.th  lpkth_7-13.th
 Submittal
   Written Specification    Packing List
 HL-Tech-Report_3-10.th  LIOTH_Tube-Heater-Precheck-8.5x11_1-13.th
 Technical Report    Application Guidelines  
 

 

Q. How does a two-stage save me money?

The RE-VERBER-RAY Two-Stage HL Series has been shown to be a more efficient heating system than standard single-stage infra-red heaters.

A minimum savings of 12% in energy usage was documented using the HL Series.  This is in comparison to single-stage infra-red heaters.
Other benefits that this study revealed were:
  • 35% reduction in on/off cycles, resulting in improved employee comfort.
  • Improved product life due to the reduction in on/off cycles.
  • Overall improved operating efficiency, reducing carbon dioxide emissions.
  • Faster recoveries. Energy is not wasted reheating the exchangers when “high-fire” is called for.
  • Design benefits. The HL Series allows you to design your building in accordance with “worst case” design temperature. Realistically, this rarely occurs and the heater will make the appropriate adjustments.

 