Infra-Red Radiant, Inc | Home Page

800-748-2678

Energy efficient, cost-saving radiant heaters

Detroit Radiant Products - Homepage

Holiday Hours

We are closed Dec 24th – Jan 1st

 

MP Series: Modulating Plus, Heater

Premium Models

MP – Modulating Series

HL3 – Two Stage Series

DX3 – Single Stage Series

Standard Models

DET3 – Two Stage Series

DES3 – Single Stage Series

Residential Garage

LD3 – Two Stage Series

LS3 – Single Stage Series

Specialty Models

SS – Stainless Steel Series

QTD – Two Stage Quad

QTS – Single Stage Quad

MP Series: Modulating Plus, Heater

The MP Series fully modulating infrared heater is the only infrared heater that allows you to select the desired performance curve that best suits your building requirements.The MP Series by Detroit Radiant Products Company raises the bar with modulating technology. This full air and gas modulation line of heaters incorporates cutting edge technology such as the selection of three different performance curves as well as a ‘Blast Mode’™ feature for extreme environmental demands.POY-awardsMP-Series-Performance-Curves-Graph V3_tubehtr_0

 

 

FeaturesSpecificationsLiteratureParts & AccessoriesFAQBuy

 

Specific Features

mp_features
  • ‘Blast Mode’™ feature allows the user to temporarily lock the heater into its highest input plus an extra 5,000 BTU’s for extreme environmental demands.
  • Choose from three performance modes.
  • Models range from 80,000 to 200,000 BTU’s.
  • Full gas modulation with corresponding air flow modulation to achieve optimal fuel utilization and comfort levels.
  • Forced high-fire start up for faster response to the environmental demand.
  • Full proportional-integral-derivative (PID) logic to reduce on/off cycles over traditional heat.

 

 

Input Range: 80,000 – 200,000 BTU/h
Lengths: 25-70 ft.
Gas Type: Natural or Propane
Combustion Chamber: Aluminized or Titanium Stabilized Steel
Radiant Tubes: Aluminized Steel
Certification: CSA Design Certified,  ANSI Z83.20b
Limited Warranty: 1-5-10 (Components-Tubes-Burner)

 

PRODUCT SPECIFICATIONS
ELECTRICAL
• 120v, 60Hz, 3-wire
• 4.8A starting, 1.1A running
INTERNAL CONTROLS
• 100% Safety Shutoff
• Microprocessor with self-learning control logic
TUBE CONSTRUCTION
• As shown at left
• 4 in. dia.,  16 ga. construction
• Interlocking swaged tube design

All tubes treated with .95 highly

emissive black tube coating.
Turbulator baffles.
REFLECTORS
• Highly polished aluminum
• Continuous overlap design
• Reflector end caps
• 0°-45° rotatable angle
• Anti-rattle tension springs
COMBUSTION AIR
• Preset 4 in. air inlet collar
• Sidewall or roof intake ready
IGNITION/SENSE
• Hot surface ignition
• Flame rod sense
• Self-diagnostic LED
VENTING
• 4″ single vent
• 6″ common vent

Consult factory for additional

venting options
GAS CONNECTION
• 36” x 3/4” S.S. Flexible Gas Connector
INLET GAS PRESSURE
Manifold @ Min. Rate:1.65 Nat. Gas; 4.10 LP
Manifold @ Max. Rate:4.80 Nat. Gas; 11.0 LP
• Min Inlet: 6.0 Nat. Gas; 12.0 LP
• Max. Inlet: 14.0 Nat. Gas; 14.0 LP
KIT CONTENTS
• All hangers & tube couplers
User manual(s) and application guidelines
Input Range: 80,000 to 200,000 BTU/h
Lengths: 25-70 Ft.
Gas Type: Natural or Propane
Combustion Chamber: Aluminized or Titanium Stabilized Steel
Radiant Tubes: Aluminized Steel
Certification: CSA Design Certified, ANSI Z83.20b
Limited Warranty: 1-5-10 (Components-Tubes-Burner)
OPTIONAL EQUIPMENT
“U” or “L” Configurations: Available (RUP, REP)
Stainless Steel Upgrades: Available
Indicator Lights: Standard
Protective Guards: Available (PG)
Side Shield Extensions: Available (SSE)
Outdoor Approval: Available (OD-KIT)

 

AVAILABLE MP SERIES MODELS & CLEARANCES

Model #
Gas* Blast Mode Rate MBH

Standard Modulating Range MBH

Length Weight

Recom. Mtg.Heights**

MP-25-80 N or LP 85  52-80 26’ – 9” 145# 12’ to 20’
MP-30-80 N or LP 85  52-80 31’ – 5” 160# 12’ to 20’
MP-30-115 N or LP 120  75-115 31’ – 5” 160# 14’ to 22’
MP-40-80 N or LP 85  52-80 41’ – 1” 190# 12’ to 20’
MP-40-115 N or LP 120
 75-115 41’ – 1” 190# 15’ to 25’
MP-40-150 N or LP 155
 97.5-150 41’ – 1” 190# 15’ to 28’
MP-50-115 N or LP 120
 75-115 50’ – 9” 235# 15’ to 28’
MP-50-150
N or LP 155  97.5-150 50’ – 9” 235# 11’ to 18’
MP-50-200 N or LP 200  130-194 50’ – 9” 235# 17’ to 30’
MP-60-150 N or LP 155  97.5-150 60’ – 5” 265# 17’ to 32’
MP-60-200 N or LP 200  130-194 60’ – 5” 265# 19’ to 37’
MP-70-200 N or LP 200  130-194 70’ – 1” 300# 19’ to 42’
MountingAngleChart
* Specify natural (N) or propane (LP) gas.
** Factory recommended mounting heights are provided as a guideline. Actual conditions may dictate variations from the above data.
Re-Verber-Ray® is a registered trademark of Detroit Radiant Products Company. Due to continuous product innovation, Detroit Radiant Products Company reserves the right to change product specifications without prior notice.
MP_cc_chart
Always maintain the published clearances to combustibles.Clearances published in MP Series manual and on warning label supersede data shown here. Place signs where necessary in accordance with ANSI Standards.

 

MP Series

mp_brochure_th liogt3_manual.th mp_manual_th
Brochure General Manual MP Insert Manual
mp_spec_th lpkth_7-13.th LIOTH_Tube-Heater-Precheck-8.5x11_1-13.th